- 2.12.0:
- SMRT Link v25.1 release
- Enable
fail_reads
input options - Extended clipping support for
MM
andML
tags
- 2.9.0:
- SMRT Link v13.0 release
- Add
--overwrite-biosample-name
option for double demux - Add
sa
,sm
, andsx
tags - Fixes for
--single-end
- 2.7.1:
- SMRT Link v12.0 release
- Allow
--single-end
to only score to score only one flank
- 2.6.0:
- Support SEGMENT read type
- Use final MM/ML basemod tags
- Bug fixes
- 2.5.0:
- Upcoming SMRT Link release
- Add
lima-undo
functionality - Support methylation tag clipping
- Add progress and ETA for
--log-level INFO
- Rename
--preset
to--hifi-preset
- Add barcoded adapter
--hifi-preset SYMMETRIC-ADAPTERS
- Fixes to support stranded HiFi BAM input
- Do not abort on empty input, but warn only
- 2.4.0:
- Fix fasta/q input and
--guess
- Output empty files for missing barcode pairs
--output-missing-pairs
- Output each barcode into its own sub-directory
--split-subdirs
- Passthrough of input ExternalResources in XML
- Add Provenance element to XML output
- Do not override Sample tag
SM
in read group if--isoseq
is used - Enable
--reuse-uuids
with--biosample-csv
- Add
--reuse-source-uuid
from input XML - Store BioSamples under WellSample
- Allow
--dataset-name
to override dataset name attribute
- Fix fasta/q input and
- 2.3.0:
- SMRT Link v10.2 release
- Add
--preset
forHIFI-SYMMETRIC
andHIFI-ASYMMETRIC
- 2.2.0:
- Add
--no-clip
to assign a barcode pair, but not clip barcode sequences from reads - Output
.consensusreadset.xml
for CCS/HiFi input - Add
--biosample-csv
to assign bio sample names to barcode pairs - Better help description for
--peek-guess
in combination with--ccs
and--isoseq
- Optional performance improvements
- Add
- 2.1.0:
- SMRT Link v10.1 release
- Do not allow double hyphen in barcode name
- 2.0.1:
- SMRT Link v10.0 release
- Minor fixes
- 2.0.0:
- Add support for FASTA and FASTQ
- Fix
-k
with by-strand HiFi reads
- 1.11.0:
- Add barcode to read groups, use one barcode pair per RG
- Fix double demux, used to clip wrongly for the second round of demuxing
- 1.10.0:
- Output N barcodes per subdirectory with
--files-per-directory N
and output splitting - BioSample awareness for XML input and split output and allow ignoring them with
--ignore-biosamples
- Increase
--window-size-mult
to3
to allow longer spacers - Do not report no adapter hits as too short inserts
- Increase
--guess
barcode score to75
if--peek-guess --ccs
are combined - Enable double demux of CCS data
- Print run time, CPU time, and peak memory consumption with
--log-level INFO
- New CLI UX
- Output N barcodes per subdirectory with
- 1.9.0:
- Add
--bad-adapter-ratio
to remove ZMWs with molecularly missing adapters - Fix rare case, where a read only matches one barcode and not a single alternative
- Fix
--no-bam
to automatically omit pbi - Allow combination of
--isoseq
with--peek-guess
- Add
- 1.8.0:
- Add clip lengths as
bx
tag - Enable single-barcode samples
- Implicitly call
--dump-clips
in--isoseq
mode
- Add clip lengths as
-
1.7.1: Fix rare-care PBI generation bug, included in SMRT Link 6.0.0
-
1.7.0: Fix corner-case bug
-
1.6.1: Fix
--min-end-score
in combination with--isoseq
- 1.6.0:
- New filter
--min-end-score
- Add latest filters to summary file
- New IsoSeq default parameters
- Fix streaming of asymmetric BAM files
- New filter
-
1.5.0: Support spacer sequence between adapter and barcode
- 1.4.0:
- New filter
--min-ref-span
and--min-scoring-regions
- Single-side library improvements
- New filter
-
1.3.0:
--peek-guess
uses only full-length ZMWs - 1.2.0:
- Streaming of split BAM files
- New fat binary build approach
-
1.1.0: IsoSeq support
- 1.0.0: Initial release, included in SMRT Link 5.1.0